MICROPROCESSOR VISIBLE
SPECTROPHOTOMETER |
Model : SSPM (Microprocessor Based) |
|
Standard Specifications |
|
|
Holographic Flashing Grating
Monochromator for precision wavelength and low stray light. |
Wavelength Range : |
325nm to 1000nm |
Spectrum Bandwidth : |
5nm |
Accuracy : |
± 2nm, Wavelength |
Repeatability : |
1nm |
Transmittance Accuracy : |
± 0.5%, Transmittance |
Repeatability : |
0.2% |
Stray Light : |
0.5% at 360nm, NaN02 |
Light Current Drift : |
0.5% / 3 min, Dark Current Drift :
0.2% / 3 min |
Automatic Zero and full
scale adjustment |
Automatic switching of
tungsten halogen lamp and Deuterium lamp |
Direct concentration read
out and concentration factor setting function
Soft touch key board, Wide range Silicon photodiode detector
RS 232 port to attach with computer for printing reports
Sample cell compartment options 5mm to 100mm
Input voltage 220-230VAC ±10%. |
|
Standard Accessories
10mm sample cell (5 Nos.), RS 232 cable, dustcover, working
/ instruction manual. |
|
|
|
UV-Vis SPECTROPHOTOMETER
|
Model :SSUV ( Single Beam Microprocessor Based) |
|
Standard Specifications
ABS for the accurate measurement of the value and
C Figures show measured value.
Wavelength Range : 195nm to 1000nm
Absorbance Range : 0.000A to 1.999A
Photometric Range : 0-200%T, -0.301- 2.000A, 0-1999C
Accuracy : ± 0.005 Abs at 1.0 Abs. ± 0.010 Abs
at 1.5 Abs
Stray Light : 0.3%T at 220nm, 360nm
Readability : ± 1 count
Data read out : single line LCD display
Data out put : RS 232C, Any Centronics dot matrix printer
Sample cell compartment options 5mm to 100mm
Optical Grating : 1200 groves/ mm resolution
Soft touch key board, Wide range Silicon photodiode detector
Light source Philips halogen, Deuterium lamp (2000h)
Standard Accessories
10mm sample cell (5 Nos.), RS 232 cable, dustcover, working
/ instruction manual.
|
|
|
SALINITY METER |
Model :SED- 29 ( Portable )
Standard Specifications
Battery operated 3-1/2 digit LCD display, range 0-40ppm, attachable
salinity cell constant value 1.0 supplied with 1x9v battery,
working / instruction manual.
|
|
|
|
SPECTROPHOTOMETER |
Model : SED-31 (10mm Path)
Standard Specifications
Range 340-960nm with facility for automatic concentration,
% transmission and absorbance measurement, wave length resolution
5nm, single display 3-1/2 digit LED display.
Standard Accessories
10mm square cavities 5 Nos., dustcover, instruction manual.
|
|
|
|
SPECTROPHOTOMETER |
Model : SED-33 (10mm & 50mm path
)
Standard Specifications
Range 340-960nm with facility for automatic concentration,
% transmission and absorbance measurement, wave length resolution
1nm, Dual display meters 3-1/2 digit and 3 digit LED display
suitable for 10mm and 50mm path length cavities / test tubes.
Standard Accessories
50mm path rectangular cavities 2 Nos., 10mm path square cavities
5 Nos., dustcover, instruction manual.
|
|
|
|
COLONY COUNTER |
Model : SED- 35
Standard Specifications
4 digit LED display 0-9999, audible buzzer confirmation of
each count, electronic auto marker counting ink pen, digital
count display can be reset at any time by RESET KEY suitable
for dish size 110mm. having 1.7x magnifying glass with focusing
system, input supply 220-230VAC ±10%.
Standard Accessories
Electronic Counting pen, 1.7x magnifying glass, dust cover,
instruction / working manual.
|
|
|
|
|
DIGITAL FLAME PHOTO
METER |
Na and
K at single aspiration, Dual channel display, Narrow band interface
filters to determine concentration of Na K, Li & Ca solution
in clinical and soil test labs. |
Model : SED- 65 |
|
Standard Specifications |
2-1/2 digit LED display, instrument supplied
with Na & K narrow band glass filters, measuring
range Na & K : 0 to 100ppm sensitivity 5ppm, Accuracy
± 2% up to 40ppm and 5% above 40ppm. Repeatability
± 2 count, Silicon photodiode detector, LPG gas
flame system, input supply 220-230VAC ± 10% |
|
Standard Accessories
Air Compressor Unit, Chimney, Air tubing, dust cover, working
/ instruction manual. |
|
|
|
DIGITAL FLAME
PHOTO METER |
Model : SED- 66 (With 4 Filters) |
|
Standard Specifications
2-1/2 digit LED display, instrument supplied with Na, K, Ca,
Li narrow band glass filters, measuring range Na & K :
0 to 100ppm sensitivity 5ppm, Accuracy ± 2% up to 40ppm
and 5% above 40ppm. Ca : 20 to 100ppm. Li : 10 to 100ppm.
Sensitivity 10ppm, Repeatability ± 2 count, Silicon
photodiode detector, LPG gas flame system, input supply
220-230VAC ± 10%
Standard Accessories
Air Compressor Unit, Chimney, Air tubing, dust cover, working
/ instruction manual. |
|
|
DIGITAL MELTING POINT
APPARATUS |
Model :S- 70
Designed for accurate determination of melting point
of various materials by uniformly heating with Silicon
oil / other media in temp. bath assembly. The Temperature
Bath assembly equipped with immersion heater, Pt100
temp. probe, built-in capillary stand to find out melting
point.
|
|
Standard Specifications |
Display |
3-1/2 digit Bright LED |
Heating Temp |
Range : 2ºC above room
temperature to 350°C |
Heating Rate |
0-100% |
Stirrer Rate |
0-100% |
Accuracy |
1% |
Heating |
Slow and Fast heating provision |
Power |
220-230VAC± 10% |
|
|
Standard Accessories
Capillary tubes (100Nos.), Teflon paddle, Cleaning